AERMOD is known to calculate exhaust concentrations, in certain situations, that are less accurate and worse than they really are. Because AERMOD’s underlying equations were developed for solid rectangular buildings having certain sizes and shapes, the model can overestimate pollutant concentrations by a factor of 4 or more when user inputs don’t fall within the ranges for which the equations were optimized.
An Equivalent Building Dimension (EBD) approach models a real building, or groups of buildings and structures, as an equivalent building that has the same airflow and dispersion patterns as the real thing, but with dimensions that fall within AERMOD’s optimal input ranges. A wind tunnel study offers a fast and convenient way to determine the equivalent building dimensions and lets users justify more accurate and frequently lower concentration levels than AERMOD might otherwise indicate.
AERMOD is a software tool developed by the American Meteorological Society (AMS)/Environmental Protection Agency (EPA) Regulatory Model Improvement Committee (AERMIC). It is the EPA’s preferred regulatory tool for modeling pollutant dispersion. The software package includes three components of relevance to this discussion.
AERMOD’s internal equations were developed and tested using only a specific range of building dimensions. If we refer to a building’s length, width, and height as L, W, and H, respectively, then AERMOD’s range of applicability based on Schulman, Strimatis and Scire (2000) is generally limited to box-shaped buildings having the following dimensions:
W=L and 0.33 ≤ W/H ≤ 1 A building that is taller than it is wide, but no more than three times as tall as it is wide | W=H and 0 < L/H ≤ 4 A building that is up to four times as long as it is tall |
AERMOD is frequently used for buildings and structures that fall outside this range, but the further one strays from these bounds, the more likely it is that AERMOD will produce inaccurate results.
Building dimension inputs for AERMOD are developed using the Building Profile Input Program (BPIP). Building plan dimensions and building tier heights are input into BPIP and the program uses various logical assumptions from past research to specify a single L-W-H and building location for each of 36 wind directions. In these calculations, BPIP assumes lattice/porous and streamlined structures are rectangular solids. In addition, BPIP will often merge separate buildings into one larger building, and may overestimate the effective building height by using the tallest tier. The net result is that in some situations BPIP will generate building dimension inputs that do not fit the theory in AERMOD.
AERMOD is known to calculate pollutant concentration results that are less accurate and often worse than is seen in reality for certain kinds of buildings and structures. Situations that are likely to cause such problems include the following.
A simple and highly effective way to improve AERMOD’s performance for these kinds of situations is by finding Equivalent Building Dimensions (EBDs). While we expect that numerical methods may one day present attractive alternatives to determine these dimensions, wind tunnel modeling currently offers the best available science.
Determining these EBDs using a wind tunnel approach involves the following sequence.
Figure 1 illustrates how this approach is used for a porous lattice structure.
To demonstrate how effectively an EBD approach can increase accuracy while reducing predicted pollutant concentrations, consider the building depicted in Figure 2 below. The building was modeled using three approaches
Each of the three approaches yields different values of L, W, and H, and each approach yields different pollutant concentrations due to a 1 gram/second emission rate from the stack indicated in red. As shown in the table, the default BPIP inputs lead to concentrations that are as much as three or more times greater than what is found using dimensions based upon a wind tunnel study.
The EPA has approved the use of the Equivalent Building Dimension approach for many cases, and EBD methods enjoy more than two decades of successful application. A brief history of the regulatory approval status of the approach follows.
A 1994 EPA Model Clearinghouse memorandum, which influenced the EPA’s approval of EBD as a useful and reliable method, reached the following conclusions (Tikvart 1994):
This memorandum is generally accepted as having established the precedent for EBD’s acceptance.
A 2011 EPA Model Clearinghouse memorandum (Bridgers 2011) concerns the first and only EBD-based study that the EPA has ever disapproved. The study was conducted for the Alcoa Davenport Works facility in Davenport, Iowa, and the memo cites several reasons why approval was not granted, including the positioning of the EBD buildings in the wind tunnel and the sizes of the roughness elements used to simulate atmospheric turbulence effects. These criticisms were concerned with the methods used to carry out the wind tunnel test and not a judgment on the approach itself.
The 2011 memo retroactively suspended all pre-2011 EPA guidance regarding the EBD approach but did not retract the endorsement of the method. In fact, the memo reasserts the EPA’s position on the EBD method and
This memo retracted the EPA’s prior guidance on how to conduct EBD determination studies in the wind tunnel but retained the agency’s general support of such methods.
The EPA is currently investigating how to re-establish its guidelines for conducting EBD studies. However, the agency’s support for the method remains strong.
At the 2012 EPA Regional/State/Local Modelers Workshop in Chicago, Roger Brode of the EPA states, “Use of wind tunnel derived ‘equivalent building dimensions’ (EBDs) needs to be reviewed and perhaps standard procedures and/or guidance developed on their use in regulatory modeling” (Brode 2012).
More recently, Steve Perry of the EPA recommended in a recent email that the Air & Waste Management Association (AWMA) Atmospheric Modeling and Meteorology (formerly AB-3) Committee provide recommendations to the EPA’s Office of Air Quality Planning and Standards (OAQPS) on how to perform future EBD studies. Indeed, the AWMA Committee plans to suggest this option at the 2014 EPA Regional/State/Local Modelers Workshop held in Salt Lake City.
The Equivalent Building Dimension approach offers an attractive way to more accurately calculate pollutant concentrations in the presence of large or unusual buildings, terrain features, and complex sites. The EBD results are frequently lower than what standard methods would predict, and this improvement in accuracy could easily represent the difference between passing and failing regulatory requirements.
CPP has a proven track record of delivering EBD-based results that meet EPA requirements. To discover how our wind tunnel services can help make your next project a success, please call our office in Fort Collins, Colorado, at +1 970 221 3371, or email us at info@cppwind.com.
Bridgers, George. Model Clearinghouse Review of Equivalent Building Dimensions for AERMOD. Research Triangle Park, NC: United States Environmental Protection Agency, October 24, 2011.
Brode, Roger W. AERMOD Development Plans: AERMIC Update. PowerPoint. Chicago, IL: United States Environmental Protection Agency, April 30, 2012.
Schulman, L.L.m D.G. Strimatis, and J. Scire, Development and Evaluation of the PRIME Plume Rise and Building Downwash Model, J. Air & Waste Manage. Assoc. 50: 378-390, 2000
Tikvart, Joseph A. Wind Tunnel Modeling Demonstration to Determine Equivalent Building Dimensions for the Cape Industries Facility, Wilmington, North Carolina. Research Triangle Park, NC: United States Environmental Protection Agency, July 25, 1994.